手机在线看片-色天堂影院-女性裸体下面张开-激情六月婷婷-成人高清在线-麻豆视频国产-亚洲午夜福利在线观看-久久久久亚洲av无码a片-91第一页-蜜桃一区二区三区四区-亚洲性图第一页-在线观看h网站-精品久久二区-免费一区二区在线观看-95国产精品

AMI System Solution
AMI System Solution


Functions
Administration

? Meter Administration
? Concentrator Administration
? Monitoring of System Components Replacement History
? Monitoring of Command and Parameter History of System Components
? Defining of Roles and Users/User Groups
? Access Control to System Components and AMR Centre
? Administration of reporting functions of AMI Centre
? Regular Automatic Backup of All Data At the Desired Time

Data Reading/Collection and Archiving

? Reading of Individual Concentrator/meter

? Reading of the Group of Concentrators/Meters

? Automated Reading According to the Sequence

? Reading On Request

? Periodical Reading on Request

? Special Reading on Request

? Data collected automatically according to the sequence set in advance include the following

  ? Daily Register Values

  ? Meter States

  ? Electricity Quality Log

  ? Event Log

  ? Load Profile

  ? Hourly Register Values

  ? State of Monthly Accounting Registers

  ? Time and Date


? Data collected from the meter on request including:

  ? Effective Voltage Values Per Phases At the Moment of Reading

  ? Effective Current Values Per Phases At the Moment of Reading

  ? Current Power–(Load Power At the Moment of Reading)

  ? Tariff Programmer

  ? Integration Period for 15-Minute Maximum Power

  ? Consumption Management Parameters

  ? Parameters for Voltage Thresholds Within Electricity Quality Log

  ? Parameters or Time Intervals of Profiles

  ? Parameters for Registers Within Profiles

  ? Parameters Related to the Presentation On Meter Display

  ? Archive States of Accounting Registers

  ? Current State of Bi-stabile Switch

  ? Meter Software Version

  ? Factory Number and Type of Meter


? Data read according to the sequence from the concentrator including:

  ? Statistics of Communication / Emergency and Regular Reports


? Data read from the concentrator upon the request including:

  ? Concentrator Data Archive

  ? Reading Programmes/Sequences

  ? Management/Parameterisation Programmes/Sequences

  ? Programmes/Sequences Execution Priorities

  ? Communication Routes

  ? Concentrator Response Time and Frequency Parameters

  ? Communication Parameters of the Concentrator

  ? Current Date and Time

  ? Other Concentrator Parameters

  ? Concentrator Software Version

  ? Records on Concentrator Parameter Changes and Adjustments

Reporting functions

? Reports with Analysis of Statuses and Alarms

? Reports on Electricity Quality

? Reports Related to Parameterization and Management

? Communication Reports

? Control Reports

? Reports Generated by the Concentrator

Data and Information Exchange with Other Information Systems and Subsystems of Electric Utility Robust protocol library for various types of DCUs and electronic energy meters, DLMS/COSEM, IEC61870-5-102 compliant